Lumirror S10

Features

S10 is a standard film for various industrial material applications, where excellent handling property is required.

Thickness

38, 50, 75, 100, 125, 188, 250µm

Typical Properties

Properties



Unit

#25
(92G)

#38
(152G)

#50
(200G)

#75
(300G)

#100
(400G)

#125
(500G)

#188
(750G)

#250
(10M)

Measurement
method

Thickness

MMV

µm

23

38

50

75

100

125

188

250

JIS C2151

Tensile strength

MD
TD

MPa

229
233

224
240

222
237

217
224

219
225

214
216

185
198

179
183

JIS C2151

Elongation at Break

MD
TD

%

169
161

185
172

189
172

167
153

163
150

167
149

184
133

194
159

JIS C2151

Thermal Shrinkage
(150°C×30min)

MD
TD

%

1.2
0.0

1.2
0.3

1.1
0.1

1.2
0.3

1.1
0.1

1.1
0.2

0.9
0.4

1.0
0.6

JIS C2151

Breakdown Voltage


kV

7.4

10.1

12.0

14.9

17.2

19.3

24.2

27.9

JIS C2151

Volume Resistivity
(20°C)



Ω/cm

6x1017

4x1017

4x1017

5x1017

4x1017

4x1017

4x1017

4x1017

JIS C2151

Dissipation Factor
(20°C,1kHz)



%

0.41

0.41

0.42

0.42

0.41

0.42

0.43

0.43

JIS C2151

Coefficient of Friction

µs
µd

-
-

0.5
0.4

0.4
0.4

0.6
0.4

0.6
0.4

0.6
0.4

0.6
0.4

-
-

-
-

ASTM D1894

Application

S10, with its standard characteristics, can be used in a wide range of industrial material applications, including FPC, membrane switches, adhesive tapes, electrical insulation, and casting release.

Standards

UL746B:RTI Electrical 105(°C) Mechanical 105(°C) UL94VTM-2(#38 to #188)

Attention

1. We accept no responsibility for results obtained by the application of the information indicated and for the safety and suitability of the products, by itself or in combination with other products. Users are advised to perform their own tests to determine the safety and suitability of such product and product combinationaccording to each of its purposes.
2. Refer to our MSDS (Material Safety Data Sheet) before use.
3. The publication is not to be taken as a license to operate under, or as a recommendation to infringe any patents.